How to read a peptide certificate of analysis (COA)
A peptide COA is only useful if you read the purity number and the identity test together. An HPLC area percentage tells you how much of the peak is the target compound; mass spectrometry tells you whether that peak is the right molecule. One without the other is not identity confirmation.
The five fields that decide whether a COA is usable
A certificate of analysis is a record, not a marketing asset. It becomes usable when it can be tied to one physical batch and one analytical method. Five fields do that work, and if any of them is missing the document cannot support a procurement decision.
- Lot or batch number — the identifier printed on the pack. Without it the report describes an unnamed batch.
- Test method — normally reversed-phase HPLC with a stated detector wavelength and column.
- Purity result — an area percentage from the integration table, not a rounded marketing figure.
- Identity result — mass spectrometry against the compound's expected molecular weight.
- Release or test date — when the lot was analysed, so age can be judged.
Reading the HPLC purity figure
Purity by HPLC is calculated from peak areas in the chromatogram: the area of the principal peak divided by the total area of all peaks, expressed as a percentage. A figure of 99.78% means the principal peak accounts for 99.78% of detected chromatographic signal under the stated method.
Two consequences follow. First, purity is method-dependent — a figure cannot be compared across differing columns, gradients or wavelengths. Second, the number is only as good as the chromatogram beside it, which is why the integration table and the trace should ship with the report rather than a percentage on its own.
| Reported as | What it means | What to check |
|---|---|---|
| ≥99% | Area-percentage purity threshold | That a chromatogram and integration table are attached |
| 99.78% | Measured result for one specific lot | That the lot number matches the pack supplied |
| No % | Absent or unmeasured | Why the result is unavailable for this lot |
Reading the MS identity record
Mass spectrometry answers a different question from HPLC. It does not measure how pure a sample is; it confirms that the principal component has the expected mass. For a peptide, the observed mass is compared with the theoretical molecular weight calculated from the sequence.
Where a compound is supplied as a salt, acetate or hydrate, the recorded form changes the expected mass. A report that states the form is more useful than one that leaves it to be inferred, because the same sequence in two different forms gives two different expected masses.
The table of contents is part of the document
Sequence or structure confirmation, storage conditions, solubility notes and handling guidance belong on the certificate too. Storage conditions in particular change what the material can be used for once it arrives, so a COA without them leaves the receiving lab to guess.
For blended or multi-component products, the useful document is a component profile — a statement of what the blend contains and confirmation that the mixture matches specification — rather than a single-compound purity figure.
Three questions worth asking before release
These are the checks that turn a document review into a decision.
- Does the lot number on the certificate match the pack in front of me?
- Is the identity test mass consistent with the stated form of the compound?
- Does the purity method description actually support the number reported?
Related questions
What does ≥99% purity mean on a peptide COA?
It means the analytical result for that lot met a 99% area-percentage threshold by the stated HPLC method. It is a specification threshold, not the measured figure — the measured result for the lot appears alongside it and should be treated as the number to record.
Is HPLC purity enough to confirm identity?
No. HPLC measures the proportion of the principal peak but does not confirm what the molecule is. Identity requires a mass spectrometry result compared against the expected molecular weight.
Why does the molecular weight differ from the sequence mass?
Salt, acetate and hydrate forms change the expected mass, and counter-ions contribute. A COA that states the supplied form explains why the observed mass differs from a bare sequence calculation.
What should be done if a COA has no lot number?
Treat the report as unverifiable. Without a lot number the document cannot be tied to the material delivered, so it cannot support release or a discrepancy claim.